Flue systems For Conventional Boilers

Single Wall Stainless Steel


Application

Condensing Devices

Conventional Devices

Indoor Installation

Pellet burning stoves

img

Product designation according to
UNI EN 1856-1: 2009

Stainless steel single wall.
TemperaturePressureCondensateCorrosionFlue liner material specificationSootfireMinimum distance to combustible material

T200

max 200 °C

P1

200 Pa

W

Wet utilization

V2

Corrosion class

L50050

Stainless steel
0.5 mm

O

No resistance
(with seal)

60

60 mm

T200

max 200 °C

P1

200 Pa

W

Wet utilization

V2

Corrosion class

L50080

Stainless steel
0.8 mm

O

No resistance
(with seal)

60

60 mm

Product designation according to
UNI EN 1856-2: 2009

Stainless steel single wall.
TemperaturePressureCondensateCorrosionFlue liner material specificationSootfireMinimum distance to combustible material

T200

max 200 °C

P1

200 Pa

W

Wet utilization

V2

Corrosion class

L50050

Stainless steel
0.5 mm

O

No resistance
(with seal)

40

40 mm

T200

max 200 °C

P1

200 Pa

W

Wet utilization

V2

Corrosion class

L50080

Stainless steel
0.8 mm

O

No resistance
(with seal)

40

40 mm

Product designation according to
UNI EN 1856-2: 2009

Stainless steel single wall.
TemperaturePressureCondensateCorrosionFlue liner material specificationSootfireMinimum distance to combustible material

T200

max 200 °C

N1

40 Pa

D

Dry utilization

V2

Corrosion class

L50050

Stainless steel
0.5 mm

G

Resistant
(without seal)

700M

700 mm

T200

max 200 °C

N1

40 Pa

D

Dry utilization

V2

Corrosion class

L50080

Stainless steel
0.8 mm

G

Resistant
(without seal)

700M

700 mm

HEAD LOSS (Pa)Ø60Ø80Ø100Ø120Ø130
Rigid pipe 1m 8 4 4 3 3
45° Elbow 5 3 3 6 6
90° Elbow 6 4 3 7 8
TRACTION RESISTANCEØ60Ø80Ø100Ø120Ø130
  5 m 5 m 5 m 5 m 5 m
ELEMENTS COMPRESSIONØ60Ø80Ø100Ø120Ø130
Maximum height 50 m 50 m 50 m 50 m 50 m
WEIGHT (kg/m)Ø60Ø80Ø100Ø120Ø130
Single wall rigid 0.76 1.05 1.25 1.52 1.63

Download